CA Drinking Water Watch

CAMP LIAHONA (0202547)

All Sampling Results From To

WELL (CA0202547_001_001)

Click to hide / show columns: Analyte Number | Analyte Name | Sampling Date | Detected Level | Less Than | RL | Counting Error (+/-) | MCL | DLR | Unit | Lab Sample ID | Lab | ELAP | Method |

Some columns are not shown for clarity. Please use the above links to unhide them.

Tips on Using Table

Analyte Number Analyte Name Sampling Date Results Counting Error (+/-) MCL DLR Unit Lab Sample ID Lab ELAP Method
Detected Level Less Than RL
Analyte Number Analyte Name Sampling Date Detected Level Less Than RL Counting Error (+/-) MCL DLR Unit Lab Sample ID Lab ELAP Method
1041 NITRITE 06-15-2022 < 0.4 1 .4 MG/L 2061516-02 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 300.0
1040 NITRATE 06-15-2022 < 0.4 10 .4 MG/L 2061516-02 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 300.0
1041 NITRITE 06-24-2019 < 0.4 1 .4 MG/L 75860011906241135N PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1040 NITRATE 06-24-2019 < 0.4 10 .4 MG/L 75860011906241135N PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1025 FLUORIDE 06-24-2019 < 0.1 2 .1 MG/L 75860011906241135I PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1929 ALKALINITY, CARBONATE 06-24-2019 < MG/L 75860011906241135G PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1919 CALCIUM 06-24-2019 46.8000000 MG/L 75860011906241135G PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1928 ALKALINITY, BICARBONATE 06-24-2019 192.0000000 MG/L 75860011906241135G PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1028 IRON 06-24-2019 < 100 300 100 UG/L 75860011906241135G PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1021 HYDROXIDE AS CALCIUM CARBONATE 06-24-2019 < MG/L 75860011906241135G PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1052 SODIUM 06-24-2019 15.5000000 MG/L 75860011906241135G PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1915 HARDNESS, TOTAL (AS CACO3) 06-24-2019 150.0000000 MG/L 75860011906241135G PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1031 MAGNESIUM 06-24-2019 8.3000000 MG/L 75860011906241135G PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1032 MANGANESE 06-24-2019 38.5000000 20 50 20 UG/L 75860011906241135G PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1927 ALKALINITY, TOTAL 06-24-2019 192.0000000 MG/L 75860011906241135G PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1042 POTASSIUM 06-24-2019 3.4900000 MG/L 75860011906241135O PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1925 PH 06-24-2019 7.2000000 pH 75860011906241135G AQUALAB 1359
1064 CONDUCTIVITY @ 25 C UMHOS/CM 06-24-2019 345.0000000 1600 UMHO/CM 75860011906241135G AQUALAB 1359
1040 NITRATE 07-17-2018 0.4000000 0.4 10 .4 MG/L 75860011807171326N AQUALAB 1359
1040 NITRATE 07-10-2018 < 0.4 10 .4 MG/L 75860011807100930N AQUALAB 1359
1038 NITRATE-NITRITE 06-07-2017 0.1630000 0.4 10 .4 MG/L 75860011706071506N PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1041 NITRITE 06-07-2017 < 0.4 1 .4 MG/L 75860011706071506N PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1040 NITRATE 06-07-2017 0.1630000 0.4 10 .4 MG/L 75860011706071506N PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1040 NITRATE 06-29-2016 < 0.4 10 .4 MG/L 75860011606291135N AQUALAB 1359
C255 NITRATE (AS NO3) 08-10-2015 < 2 45 2 MG/L 75860011508100715N AQUALAB 1359
1041 NITRITE 08-05-2014 < 400 1000 400 UG/L 75860011408051440N PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
C255 NITRATE (AS NO3) 08-05-2014 2.6500000 2 45 2 MG/L 75860011408051440N PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1038 NITRATE-NITRITE 07-10-2013 < 400 10000 400 UG/L 75860011307100800N EUROFINS EATON ANALYTICAL POMONA 2813
1041 NITRITE 07-10-2013 < 400 1000 400 UG/L 75860011307100800N EUROFINS EATON ANALYTICAL POMONA 2813
C255 NITRATE (AS NO3) 07-10-2013 < 2 45 2 MG/L 75860011307100800N EUROFINS EATON ANALYTICAL POMONA 2813
C255 NITRATE (AS NO3) 09-20-2011 < 2 45 2 MG/L 75860011109201245N PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1041 NITRITE 09-20-2011 < 400 1000 400 UG/L 75860011109201245N PRECISION ENVIRO-TECH ANALYTICAL LAB 2387
1038 NITRATE-NITRITE 09-20-2011 < 400 10000 400 UG/L 75860011109201245N PRECISION ENVIRO-TECH ANALYTICAL LAB 2387

RL – Reporting Level means the level to which the laboratory reported the presence of an analyte. For radionuclides, Reporting Level is the MDA95.

DLR – Detection Limit for purposes of Reporting (DLR) means the designated minimum level at or above which any analytical finding of a contaminant in drinking water resulting from monitoring required under Chapter 15 of Title 22 shall be reported to the State Board (California Code of Regulations Section § 64400.34)

For addtional definitions, please refer to our data dictionary.