MINTURN HULLER (2400250)
All
Sampling Results From To
WELL 2022
(CA2400250_002_002)
Click to hide / show columns: Analyte Number |
Analyte Name |
Sampling Date |
Detected Level |
Less Than |
RL |
Counting Error (+/-) |
MCL |
DLR |
Unit |
Lab Sample ID |
Lab |
ELAP |
Method |
Some columns are not shown for clarity. Please use the
above links to unhide them.
Tips on Using Table
Analyte Number |
Analyte Name |
Sampling Date |
Results |
Counting Error (+/-) |
MCL |
DLR |
Unit |
Lab Sample ID |
Lab |
ELAP |
Method |
Detected Level |
Less Than |
RL |
Analyte Number |
Analyte Name |
Sampling Date |
Detected Level |
Less Than |
RL |
Counting Error (+/-) |
MCL |
DLR |
Unit |
Lab Sample ID |
Lab |
ELAP |
Method |
1041 |
NITRITE |
03-06-2024 |
|
< |
0.2 |
|
1 |
.4 |
MG/L |
GGC0238-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 300.0 |
1040 |
NITRATE |
03-06-2024 |
|
< |
0.4 |
|
10 |
.4 |
MG/L |
GGC0238-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 300.0 |
1041 |
NITRITE |
02-06-2023 |
|
< |
0.2 |
|
1 |
.4 |
MG/L |
GFB0262-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 300.0 |
1040 |
NITRATE |
02-06-2023 |
|
< |
0.4 |
|
10 |
.4 |
MG/L |
GFB0262-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 300.0 |
1925 |
PH |
08-22-2022 |
7.66 |
|
0.1 |
|
|
|
pH |
GEH1073-01 |
CRANMER ENGINEERING, INC. |
1936 |
SM 4500-H+B |
1919 |
CALCIUM |
08-22-2022 |
11.5 |
|
0.05 |
|
|
|
MG/L |
GEH1073-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 200.7 |
1915 |
HARDNESS, TOTAL (AS CACO3) |
08-22-2022 |
43.8 |
|
0.1 |
|
|
|
MG/L |
GEH1073-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 200.7 |
1052 |
SODIUM |
08-22-2022 |
15.2 |
|
2 |
|
|
|
MG/L |
GEH1073-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 200.7 |
1041 |
NITRITE |
08-22-2022 |
|
< |
0.2 |
|
1 |
.4 |
MG/L |
GEH1073-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 300.0 |
1040 |
NITRATE |
08-22-2022 |
1.04 |
|
0.4 |
|
10 |
.4 |
MG/L |
GEH1073-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 300.0 |
1031 |
MAGNESIUM |
08-22-2022 |
3.67 |
|
0.1 |
|
|
|
MG/L |
GEH1073-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 200.7 |
1032 |
MANGANESE |
08-22-2022 |
|
< |
20 |
|
50 |
20 |
UG/L |
GEH1073-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 200.8 |
1028 |
IRON |
08-22-2022 |
|
< |
100 |
|
300 |
100 |
UG/L |
GEH1073-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 200.7 |
1025 |
FLUORIDE |
08-22-2022 |
|
< |
0.1 |
|
2 |
.1 |
MG/L |
GEH1073-01 |
CRANMER ENGINEERING, INC. |
1936 |
EPA 300.0 |
1929 |
ALKALINITY, CARBONATE |
08-22-2022 |
|
< |
5 |
|
|
|
MG/L |
22H1467-01 |
CLS LABS |
1233 |
SM 2320 B |
1928 |
ALKALINITY, BICARBONATE |
08-22-2022 |
67 |
|
5 |
|
|
|
MG/L |
22H1467-01 |
CLS LABS |
1233 |
SM 2320 B |
1927 |
ALKALINITY, TOTAL |
08-22-2022 |
55 |
|
5 |
|
|
|
MG/L |
22H1467-01 |
CLS LABS |
1233 |
SM 2320 B |
1064 |
CONDUCTIVITY @ 25 C UMHOS/CM |
08-22-2022 |
140 |
|
1 |
|
1600 |
|
UMHO/CM |
22H1467-01 |
CLS LABS |
1233 |
SM 2510 B |
1021 |
HYDROXIDE AS CALCIUM CARBONATE |
08-22-2022 |
|
< |
5 |
|
|
|
MG/L |
22H1467-01 |
CLS LABS |
1233 |
SM 2320 B |
RL – Reporting Level means the level to which the laboratory reported the presence of an analyte. For radionuclides, Reporting Level is the MDA95.
DLR – Detection Limit for purposes of Reporting (DLR) means the designated minimum level at or above which any analytical finding of a contaminant in drinking water resulting from monitoring required under Chapter 15 of Title 22 shall be reported to the State Board (California Code of Regulations Section § 64400.34)
For addtional definitions, please refer to our
data dictionary.
|
|
|