USFS CHERRY VALLEY CAMPGD (5500138)

All Sampling Results From To

WELL 1 (CA5500138_002_002)

Click to hide / show columns: Analyte Number | Analyte Name | Sampling Date | Detected Level | Less Than | RL | Counting Error (+/-) | MCL | DLR | Unit | Lab Sample ID | Lab | ELAP | Method |

Some columns are not shown for clarity. Please use the above links to unhide them.

Tips on Using Table

Analyte Number Analyte Name Sampling Date Results Counting Error (+/-) MCL DLR Unit Lab Sample ID Lab ELAP Method
Detected Level Less Than RL
Analyte Number Analyte Name Sampling Date Detected Level Less Than RL Counting Error (+/-) MCL DLR Unit Lab Sample ID Lab ELAP Method
1041 NITRITE 05-05-2024 < 0.4 1 .4 MG/L 2405067-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 300.0
1040 NITRATE 05-05-2024 < 0.4 10 .4 MG/L 2405067-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 300.0
1040 NITRATE 10-09-2023 < 0.4 10 .4 MG/L 2310204-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 300.0
1930 TDS 10-05-2022 160 1 1000 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 SM 2540 C
1929 ALKALINITY, CARBONATE 10-05-2022 < 1 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 SM 2320 B
1928 ALKALINITY, BICARBONATE 10-05-2022 87.8 1 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 SM 2320 B
1927 ALKALINITY, TOTAL 10-05-2022 87.8 1 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 SM 2320 B
1925 PH 10-05-2022 6.89 0.01 pH 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 SM 4500-H+B
1919 CALCIUM 10-05-2022 18.0 1.5 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 200.7
1915 HARDNESS, TOTAL (AS CACO3) 10-05-2022 63.9 1 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 SM 2340 B
1064 CONDUCTIVITY @ 25 C UMHOS/CM 10-05-2022 260 1 1600 UMHO/CM 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 SM 2510 B
1055 SULFATE 10-05-2022 < 1 500 .5 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 300.0
1052 SODIUM 10-05-2022 21.5 2 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 200.7
1042 POTASSIUM 10-05-2022 4.13 1 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 200.7
1041 NITRITE 10-05-2022 < 0.4 1 .4 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 300.0
1040 NITRATE 10-05-2022 < 0.4 10 .4 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 300.0
1032 MANGANESE 10-05-2022 79.9 20 50 20 UG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 200.8
1031 MAGNESIUM 10-05-2022 4.62 1.5 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 200.7
1028 IRON 10-05-2022 < 100 300 100 UG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 200.7
1025 FLUORIDE 10-05-2022 < 0.1 2 .1 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 300.0
1021 HYDROXIDE AS CALCIUM CARBONATE 10-05-2022 < 1 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 SM 2320 B
1017 CHLORIDE 10-05-2022 27.5 1 500 MG/L 2100514-01 PRECISION ENVIRO-TECH ANALYTICAL LAB 2387 EPA 300.0

RL – Reporting Level means the level to which the laboratory reported the presence of an analyte. For radionuclides, Reporting Level is the MDA95.

DLR – Detection Limit for purposes of Reporting (DLR) means the designated minimum level at or above which any analytical finding of a contaminant in drinking water resulting from monitoring required under Chapter 15 of Title 22 shall be reported to the State Board (California Code of Regulations Section § 64400.34)

For addtional definitions, please refer to our data dictionary.