CA Drinking Water Watch

Links

PS Code Transition

Water System Details

Water System Facilities  

Monitoring Schedules

Monitoring Results

Monitoring Results By Analyte

Lead And Copper Sampling

Violations/Enforcement Actions

Site Visits

Consumer Confidence Reports

  • Templates
  • 2023
  • 2022
  • 2021
  • 2020
  • 2019
  • 2018

Lead Service Line Documents

Return Links

Water System Search

County Map

Glossary

Contact Info

 

 

Monitoring Schedules (new format)


Water System No. : CA4910005 Federal Type : C
Water System Name : HEALDSBURG, CITY OF State Type : C
Principal County Served : SONOMA Primary Source : GU
Status : A Activity Date : 06-12-2013
Distribution System Classification : D3 Max Treatment Plant Classification : T3

NOTICE TO USERS OF THE DATABASE: Users of this database should use care in interpreting these data. Data that does not meet Division of Drinking Water (DDW) data quality objectives is not included and the provided data may not be representative of water served by a water system. For example, the presence of a contaminant in a particular source of water at a given concentration does not necessarily mean that the water from that source was served by the water system to its customers, or, if served, that the contaminant was present at that concentration. Water systems may not use certain sources or may treat or blend them prior to serving the water to customers.

Questions about contaminants in particular sources are best addressed by the specific public water system, or by the associated DDW district office.

The Division of Drinking Water's (DDW's) drinking water quality monitoring schedules identify upcoming required testing of drinking water for water systems in California. These documents should not be used for determining whether water systems are in compliance with monitoring requirements. The purpose for providing these monitoring schedules is to allow water systems to verify that their sampling and analyses have been incorporated into the DDW database and to identify upcoming required monitoring/sampling events.

Notes for Water Systems:
1. The monitoring notification documents should be considered "draft," in that they will change with subsequent updates, and as monitoring data are submitted, or as monitoring schedules are revised .
2. The monitoring notification documents are derived from the DDW Water Quality database and from schedules maintained by DDW districts.
3. If your upcoming monitoring or your data identified as "DUE" are not in agreement with this document, or if your have been advised of any increased monitoring that is not reflected in the report for a particular source, please contact your District Engineer or LPA representative. For a map of the districts, please click here.
4. If your notification report for a source is blank, this does not necessarily indicate compliance with all monitoring requirements.
5. These notification reports may not reflect compliance with initial monitoring for newly regulated constituents, or constituents that require special monitoring frequencies. For example, the DDW database is unable to accurately forecast the vulnerable non-volatile synthetic organic chemical (SOC) frequency for large water systems serving over 3,300 people of 2 quarters every 3 years.
5a. For radionuclide compliance monitoring, a gross alpha (GA) particle activity measurement may be substituted for other measurements when the assigned value is less than 5 pCi/L. The assigned value is calculated by adding 0.84 of the counting error (CE) to the gross alpha result (GA + 0.84xCE). If the assigned value is greater than 5 pCi/L, then the water sample must be analyzed for uranium per Section 64442, Article 5, Chapter 15, Division 4, Title 22 of the California Code of Regulations. In addition, if the difference between the assigned value and the uranium measurement [GA + (0.84 x CE) - U] is greater than 5 pCi/L, analysis for Radium-226 and Radium-228 is required. If you have specific questions, contact your DDW District Office.
6. Some Nitrate (as N) results under storet code 00618, will have a result of �N/A� which stands for �Not Applicable.� This stems from the change in regulation requiring that all nitrate sampling be reported as Nitrate (as N) starting January 1, 2016. Prior nitrate sampling was reported as Nitrate (as NO3). With this change in nitrate reporting requirements, the monitoring schedules have captured the last date of Nitrate (as NO3) sampling and applied it to Nitrate (as N) in determining the next due date [unless there have been Nitrate (as N) samples collected]. The Nitrate (as NO3) result, however, does not carry over to Nitrate (as N) which is why there may be a notation in the �Constituent Identification� column to reference storet code 71850 for the last nitrate result. In these instances, the �Constituent Identification� column will say, �NITRATE (as N) � [see 71850].� Any questions should be referred to your District Engineer.  
Test Legends:
  • PS Code = Primary Station Code; used by laboratories to upload water quality data
  • Old PS Code = (Water System Number)-(Sample Point ID)
  • New PS Code = (Water System Number)_(Facility ID)_(Sampling Point ID) to be used by laboratories to upload water quality data when CLIP (California Laboratory Intake Portal) is implemented
  • Facility Status: A = Active; P = Proposed
  • Certain PS Codes have been removed from this table as they are not intended to have water quality data electronically reported. As an example, a water system may have a PS Code to represent Well 01 and another PS Code to represent Well 01 Chlorination. However, water quality data should only be reported to the PS Code for Well 01. The PS Code for Well 01 Chlorination would be removed from the list to avoid confusion in uploading data. If you notice that a PS Code is missing from the list that may be needed for uploading water quality data, please contact your District Office or Local County Primacy Agency.

Click to hide / show columns: Old PS Code | New PS Code | Facility ID | Sample Point ID | Sample Point Name | Status


Monitoring Schedules for All Sampling Points
Monitoring Schedule for Individual Sampling Points
Old PS Codes New PS Codes Facility ID Sample Point ID Sample Point Name Status
4910005-001 CA4910005_001_001 001 001 GAUNTLETT WELL 01 A
4910005-002 CA4910005_002_002 002 002 GAUNTLETT WELL 02 (SURF INFLUENCE) A
4910005-003 CA4910005_003_003 003 003 GAUNTLETT WELL 03 A
4910005-004 CA4910005_004_004 004 004 GAUNTLETT WELL 04 A
4910005-005 CA4910005_005_005 005 005 FITCH WELL 01 A
4910005-006 CA4910005_006_006 006 006 FITCH WELL 02 A
4910005-010 CA4910005_010_010 010 010 DRY CREEK WELL 01 A
4910005-011 CA4910005_011_011 011 011 FITCH WELL 05 A
4910005-012 CA4910005_012_012 012 012 FITCH WELL 06 A
4910005-013 CA4910005_013_013 013 013 DRY CREEK WELL 02 A
4910005-014 CA4910005_014_014 014 014 DRY CREEK WELL 03 A
4910005-015 CA4910005_015_015 015 015 DRY CREEK WELL 04 A
4910005-016 CA4910005_016_016 016 016 DRY CREEK WELL 05 A
4910005-017 CA4910005_017_017 017 017 TREATMENT PLANT - GAUNTLETT 1,2,3,4-TRTD A
4910005-018 CA4910005_018_018 018 018 TREATMENT PLANT - FITCH 1,2,5,6 - TREATD A
4910005-019 CA4910005_019_019 019 019 TREATMENT PLANT - DRY CREEK WELLS 1-5-TD A
4910005-028 CA4910005_028_028 028 028 GAUNTLETT TREATMENT PLANT INFLUENT A
4910005-020 CA4910005_DST_020 DST 020 DIST-238 CENTER STREET - TREATED A
4910005-021 CA4910005_DST_021 DST 021 DIST - 303 BURGUNDY RD A
4910005-022 CA4910005_DST_022 DST 022 DIST-304 SUNNYVALE DR - TREATED A
4910005-023 CA4910005_DST_023 DST 023 DIST-985 HEALDSBURG AVE - TREATED A
4910005-024 CA4910005_DST_024 DST 024 DIST-825 PORDON LANE - TREATED A
4910005-025 CA4910005_DST_025 DST 025 DIST-601 HEALDSBURG AVE - TREATED A
4910005-026 CA4910005_DST_026 DST 026 DIST-2600 N FITCH MTN RD - TREATED A
4910005-027 CA4910005_DST_027 DST 027 DIST-1145 ORCHARD ST - TREATED A
4910005-029 CA4910005_DST_029 DST 029 DIST - 5...* A
4910005-030 CA4910005_DST_030 DST 030 DIST - 1400 PINON DRIVE A
4910005-031 CA4910005_DST_031 DST 031 DIST - 1...* A
4910005-LCR CA4910005_DST_LCR DST LCR Lead and Copper Sample Sites ** A
Old PS Codes Old PS Codes Facility ID Sample Point ID Sample Point Name Status
 
*Please refer to the Stage 2 DBP Monitoring Plan Approval Letter for full sample point names.
**Please use this PS Code for all lead and copper samples.